What was found
FWD CARGO UNDER FLOOR AREA AT FRAME 27, STRINGERS 43 & 44L, SHEAR TIE HAS SURFACE CORROSION. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-42-11 P.12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO UNDER FLOOR AREA AT FRAME 27, STRINGERS 43 & 44L, SHEAR TIE HAS SURFACE CORROSION. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-42-11 P.12.