What was found
FWD CARGO UNDER FLOOR UNDER AREA AT FRAME 31, STRINGERS 40-41RT SHEAR TIE HAS CORROSION. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-42-11, P.12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO UNDER FLOOR UNDER AREA AT FRAME 31, STRINGERS 40-41RT SHEAR TIE HAS CORROSION. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-42-11, P.12.