What was found
FWD CARGO UNDER FLOOR AREA AT FRAME 31, STRINGER 43 - 44L SHEAR TIE CORRODED. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-42-11, P.1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO UNDER FLOOR AREA AT FRAME 31, STRINGER 43 - 44L SHEAR TIE CORRODED. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51-42-11, P.1.