What was found
SHEAR TIE FRAME 29 BETWEEN STRINGERS 42 - 43R HAS A SURFACE CORROSION. FOUND TO BE OUT OF LIMITS IAW SRM 51-73 -11, AND DRAWING D53230398. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51- 42-11 PAR 2E.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHEAR TIE FRAME 29 BETWEEN STRINGERS 42 - 43R HAS A SURFACE CORROSION. FOUND TO BE OUT OF LIMITS IAW SRM 51-73 -11, AND DRAWING D53230398. REMOVED AND REPLACED THE SHEAR TIE IAW SRM 51- 42-11 PAR 2E.