What was found
SHEAR TIE CORRODED BEYOND LIMITS 50% MATERIAL LOSS AT FRAME 30, STRINGER 41-42R. REMOVED AND REPLACED THE SHEAR TIE IAW 51-42-11-001, REV 119, AND SRM 51-44-11-001.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHEAR TIE CORRODED BEYOND LIMITS 50% MATERIAL LOSS AT FRAME 30, STRINGER 41-42R. REMOVED AND REPLACED THE SHEAR TIE IAW 51-42-11-001, REV 119, AND SRM 51-44-11-001.