What was found
FWD CARGO BAY HAS A CORRODED SHEAR TIE FRAME 34 BETWEEN STRINGERS 41 - 42R. REMOVED CORROSION FROM SHEAR TIE, ORIGINAL THICKNESS .055", MINIMUM ALLOWABLE REMAINING THICKNESS .051", ACTUAL REMAING THICKNESS .045" FOUND TO BE OUT OF LIMITS IAW A320 S RM 51-73-11 AND AIRBUS DWG D53230513. REMOVED AND REPLACED SHEAR TIE IAW A320 SRM 51-42-11.