SLIDE ARMED LIGHT ABOVE THE R2 DOOR ILLUMINATED WITH DOOR DISARMED. FOUND BOTH PROXIMITY SENSORS FAILED CLOSED. REPLACED BOTH SENSORS IAW WDM 25-66-11 AND AMM 25-66-11.