As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WHILE PERFORMING EA 3351-01167 LENS MOD OP6 R-2 DOOR STEP 12 REQUIRES OPS CHECK OF EMERGENCY LIGHTS.R-2 DOOR FAILED.LIGHT COMES ON THEN GOES RIGHT OUT. REMOVED AND REPLACED THE BATTERY ASSY OPS CHECKS GOOD REF AMM 33-51-06. ADD EMP:U335635