What was found
HORIZONTAL BULHEAD WEB BS 1287 BETWEEN LBL 18.3, AND 25.7 FOUND CRACKED, THE BULKHEAD WEB FOUND CRACKED. TRIMMED OUT AREA IAW DRAWING 624W0008, SHT 8. HFEC INSPECTION CARRIED OUT IAW NTM PART 6, 51-00-01 PROC 2, REV 71, REV, NO CRACK WAS FOUND AT TRIMMED AREA. PLUG INSTALLED IAW DRAWING 624W0008, SHT 8.