What was found
MAIN CABIN FWD FLOOR SUPPORT BETWEEN BS 310 AND 324, RBL 40 CORRODED ON UPPER SURFACE AT MULTIPLE AREAS. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DETAIL III, ALLOWABLE DAMAGE I. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, PG 7, PAR 7D, AND DWG 141N5160.