What was found
RT EXTERIOR AFT OVERWING EXIT EMERGENCY LIGHT AND SLIDE ESCAPE LIGHT WILL NOT COME ON DURING TEST. REPLACED POWER SUPPLY REF AMM 33-51-06. OPS CHECKED OK. INSPECTED O/W EXIT LIGHT REF AMM 33-51-06.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT EXTERIOR AFT OVERWING EXIT EMERGENCY LIGHT AND SLIDE ESCAPE LIGHT WILL NOT COME ON DURING TEST. REPLACED POWER SUPPLY REF AMM 33-51-06. OPS CHECKED OK. INSPECTED O/W EXIT LIGHT REF AMM 33-51-06.