What was found
FOUND A CORRODED INTERCOSTAL BETWEEN BS 740 - 760, STRINGER 24 - 25L. BLENDED AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53, FIG 101, DETAIL V. REMOVED AND REPLACED THE INTERCOSTAL IAW SRM 51-40-02, PAGE 2 & 4 AND DWG 143N5320.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND A CORRODED INTERCOSTAL BETWEEN BS 740 - 760, STRINGER 24 - 25L. BLENDED AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53, FIG 101, DETAIL V. REMOVED AND REPLACED THE INTERCOSTAL IAW SRM 51-40-02, PAGE 2 & 4 AND DWG 143N5320.