As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CARGO FLOOR STRINGER AT STA 634 TO STA 705 LBL 10.45 HAS CORROSION AROUND NUTPLATES. REMOVED CORROSION ON FWD CARGO FLOOR STR AROUND NUT PLATES FROM STA 634 TO STA 705 LBL 10.45 FOUND TWO AREAS (AREA 1 L=3.3" X W= .8" MAT REMAINING .027 AND AREA 4 L=3.0" W=.6 MAT REMAINING .027 ) OUT OF LIMITS IAW SRM 53-00-53 FIG 101. REMOVED AND RE PLACED FLOOR STR P/N 143N370-40 PO SAG189017 IAW DWG NO 143N001 0 AND SRM 51-40-02 PAG 2-7.