What was found
CLIMBING THRU 5000 FEET RECEIVED A FLAPS EICAS, CONFIG LIGHT, MASTER WARNING AND AURAL WARNING. SPD LIM IN AMBER AT BOTTOM OF SPEED TAPE. EMERGENCY DECLARED. PERFORMED RESISTANCE AND INDUCTACE CHECKS ON PROXIMITY SENSORS S244 AND S266 IAW AMM 32-61-99-706-113, STEP E(2). RESISTANCE S244: 18.2 OHMS; S266: 18.46 OHMS. ACCOMPLISHED FULL STRUT SERVICE IAW AMM 12-15-02. ACCOMPLISHED WARNING SYSTEM TEST IAW AMM31-51-00, ALL TESTS NORMAL NO FAULTS NOTED. ACCOMPLISHED TCAS BITE IAW FIM34-45 TASK 807 AND AMM34-45-00, NO FAULTS NOTED. ACCOMPLISHED STALL WARNING TEST IAW AMM 27-32-00, ALL INDICATIONS NORMAL.