As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CARGO FLOOR SUPPORT STR LBL 10.45 BETWEEN APPROX BS 1200 AN D BS 1343.5 HAS CORROSION ON MULTIPLE AREAS BOTH UPPER ABD LOWER SURFACES, 209-057. REMOVED CORROSION ON AFT CARGO FLOOR STRINGER BETWEEN STA 1200-1 343.5 LBL 10.45 FOUND TO BE OUT OF LIMITS IAW SRM 53-00- 53 FIG 101 DETAIL V ALLOWABLE DAMAGE 1 L=7.00 W=1.00 D=.021. REMOVED AND REPLACED NEW FLOOR STRINGER P/O SAG189017 IAW DWG 146N5390.