What was found
MAIN CABIN, RT CREASE BEAM AT STRINGER 17R BETWEEN BS 1120 AND BS 1140 HAS CORROSION, FOUND TO BE OUT OF LIMITS IAW SRM 53-40-13-A1. FABRICATED AND I NSTALLED A NEW DOUBLER IAW SRM 51-40-02 AND DWG 144N5211.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN, RT CREASE BEAM AT STRINGER 17R BETWEEN BS 1120 AND BS 1140 HAS CORROSION, FOUND TO BE OUT OF LIMITS IAW SRM 53-40-13-A1. FABRICATED AND I NSTALLED A NEW DOUBLER IAW SRM 51-40-02 AND DWG 144N5211.