As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BULK CARGO FLOOR SUPPORT STR LBL 2.9 FROM BS 1 445.6 TO BS 1500 HAS CORROSION ON MULTIPLE AREAS. REMOVED CORROSION AT BULK CARGO FLOOR SUPPORT STR LBL 2.9 FROM BS 1445.6-1500 MAX MATERIAL LOSS .031" FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53 ADI DETAIL V. REMOVED AND REPLACED STR IAW DWG 146N5390 AND SRM 51-40-02 PAR 7D PG 6- 7.