What was found
INSPECTION OF THE RT AFT EMERGENCY EXIT DOOR FOUND CORRODED AT LOWER FWD INNER ANGLE. REMOVED AND REPLACED THE ANGLE IAW SRM 51-72-11-911-001, 51-42-11-001-2D, AND 2.E.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION OF THE RT AFT EMERGENCY EXIT DOOR FOUND CORRODED AT LOWER FWD INNER ANGLE. REMOVED AND REPLACED THE ANGLE IAW SRM 51-72-11-911-001, 51-42-11-001-2D, AND 2.E.