What was found
AFT CARGO STRINGER SPLICE 22L, BS 1460 CORRODED, FOUND OUT OF LIMITS IAW SRM 53-00-53-A1. REMOVED AND REPLACED THE STRINGER SPLICE IAW SRM 51-40-02, PG 1-10, AND DWG 146N3400.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO STRINGER SPLICE 22L, BS 1460 CORRODED, FOUND OUT OF LIMITS IAW SRM 53-00-53-A1. REMOVED AND REPLACED THE STRINGER SPLICE IAW SRM 51-40-02, PG 1-10, AND DWG 146N3400.