What was found
FOUND THE FRAME UPPER FLANGE DENTED BS 1420, STRINGER 25L TO 26L, FOUND OUT OF LIMITS IAW SRM 53-00-07-A1-F. CUTOUT AREA, FABRICATED, AND INSTALLED A REPAIR IAW SRM 53-00-07-R5-F 201.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND THE FRAME UPPER FLANGE DENTED BS 1420, STRINGER 25L TO 26L, FOUND OUT OF LIMITS IAW SRM 53-00-07-A1-F. CUTOUT AREA, FABRICATED, AND INSTALLED A REPAIR IAW SRM 53-00-07-R5-F 201.