What was found
LT AFT EMERGENCY EXIT DOOR CUTOUT. LOWER SURFACE BETWEEN THE LATCHES FOUND CORRODED AFTER CHECKING MATING SURFACE OF CORRODED HATCH. REMOVED CORRODED BEAM AT LT AFT EMERGENCY EXIT DOOR LOWER BEAM. MATCH DRILLED NEW BEAM AND INSTALLED NEW BEAM RESTORED SURFACE PROTECTION IAW SRM 51-72-11-911-001 COMPLIED WITH.