What was found
SUPERTUG TEAM SPOTTED FUSELAGE DAMAGE AT GATE TOW UP. DAMAGE IS LOCATED 42" FWD OF TOP FWD CORNER OF L1 ENTRY DOOR. SHEET METAL DAMAGE LOCATION BETWEEN SL-5 AND SL-6 AT APROX STATION BS 272. DENT MEASURES 1.6" X 1.2" WITH A DEPTH OF .030". GOUGE ON DENT BLENDED AND REMOVED ACCOMPLISHED STEP (1) - DVI OF SURROUNDING AREA IAW ESC 180707-427-1. ACCOMPLISHED STEP (2) - BLENDED DAMAGE IAW AVO ESC 180707-427-1. REFERENCE ESC180707-427-1 STEP NR 3. PERFORMED HFEC OF SPECIFIED AREA AS PER 737 NDT MANUAL PART 6 CHAPTER 51-00-00. NO CRACKS DETECTED AT THIS TIME. MEASUREMENT OF GRIDDED AREA AS PER NTM MANUAL PART 4-00-04-02. REFERENCE ESC180707-427-1 STEP NR 4. PERFORMED USI THICKNESS ACCOMPLISHED STEP (5).