What was found
A CRACK INDICATION R1 DOOR STOP FTG NO. 7 HOLE NO. 3 AT FR20 AT 5 O''CLOCK POSITION AD 2017-22-03 ON HAECO LCQ REF 9290260 SPEC A 3NB-53-4-6304 GENERATED BY V923744 REPAIRED PER EC/RA 5311-02017 R/H FR16 DOOR STOP #7 HOLE #3, FR2 0 DOOR STOP 1 HOLE #3, FR20 DOOR STOP 7 HOLE #3. DTA ACCOMPLISH THE INITIAL INSP PER EC/RA 5311-02017 ON OR BEFORE A/C REACHES ADD EMP:V914418 39,876 FC. ACCOMPLISH REPEAT INSPECTIONS AT INTERVALS NOT TO EXC EED 13,100 FC THEREAFTER. APPROVED TO CARRY PER ECRA 5311-02017. ACCOMPLISH INITIAL INSPECTION PER PART 2 OF ECRA 5311-02017 ON OR BEFORE THE A/C REACHES 29876 TOTAL F/CS. ACCOMPLISH REPEAT INSPECTIONS AT INTERVALS NOT TO EXCEED 13100 F/C''S THEREAFTER. TOMC-APPROVAL FROM SC1ELBYC COMMENT REVIEWED QC REVIEWED RECORDS UPDATE INIT: WITHIN 39,876 TAFC RIR: EVERY 13,100 FC THEREAFTER...SN/V750322