What was found
SEVERAL FASTENER HOLES FOR R2 DOOR FR68 INNER CAP JOINT GUSSET PLATES AT STRINGERS 10,12,14,AND 16 ARE VISUALLY OUT OF ROUND AND ALSO NEED TO BE DE-BURRED. (DESCREPANT HOLES ARE MARKED) A3NB-5 3-3-6354 GENERATED BY V061690 ON LCQ REF NR 9296643 STEP REAMED HOLES TO A ROUND AND TRUE CONDITION IAW SRM 51- 44-11-001, FABRICATED 1EA GUSSET PLATE FOR STR16 IAW SRM 53 -41-69-001, INSTALLED FR68 STR16 GUSSET PLATE IAW SRM 51-42 -11-001