What was found
AFT FUSELAGE EXTERNAL SURFACE FR 63 STR 41L HAS A DENT - A3NB-05 -3-6003 - GENERATED BY N078570 AT HAECO LCQ PER N/R 9297297 REPAIRED AFT FUSELAGE SKIN AT FR63, STR 41L PER SRM 53-00-11-800 -004.REMOVED DOUBLER AND CLEAT AT FR63 STR41L-STR42L. FABBED & I NSTALLED DOUBLER & CLEAT PER SRM53-00-11-300-004 & SRM51-44-11- 001 & DWG D53470801. TREATED & PRIMED & TOP COATED. SRI REQUIRED AT INSP THRESHOLD FROM TIME OF REPAIR AT 24,600 FC, 49,200 FH & SUBSEQUENT INSPS AT INTERVAL OF 2,900 FC, 5,800 FH. INSP METHODS NTM51-10-15 & 16. NOMINAL SKIN THICKNESS 0.063". DOUBLER THICKNESS 0.071". FILLER THICKNESS 0.063". CLEAT THICKNESS 0.063". HAECO NR 23297. OKAY TO DIP INSPECTION THRESHOLD OF 24600FC/49200FH WITH SUBSEQUENT INSP