What was found
RT ENG EGT LIM EXCEEDED ON CLIMBOUT ...SLIGHT THROTTL REDUC BROU GT TEMP INTO LIMS CJ HARNESS REPLACED, REF L/P 8182160. R+R S4 PROBE IAW AMM 77-21-01-400-801-FOO DUE TO DASHES ON EEC BITE. PERFORMED T49.5 PROBE AND EGT SYS INSP IAW AMM 77-21-01-200-801-F00, ALL VALUES WITHIN LIMITS. RAN ENG AT IDLE, ALL T49.5 PARAMETERS NORMAL. REF L/P 8183730 FOR POWER ASSURANCE CHECK. ADD EMP:U115824 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1647299 SN OFF 8456 IPC REFERENCE # PROBE, THERMOCO OFF 29-7721-9-9001 8156 ON 29-7721-9-9001 7072