What was found
RIGHT HAND INBOARD FLAP, INBOARD TRACK FWD SUPPORT FITTING SEPARATING FROM LANDING GEAR SUPPORT BEAM. 3/16 GAP WITH CORROSION. REMOVED RH INBOARD FLAP,INBOARD TRACK FOWARD SUPPORT FITTING IAW MM 57-54-01-004-001 PER ECRA 5740-02900 STEPS1.1 & 1.6 HFEC CW ON SURFACE PER PART 6 & HFEC CW ON OPEN HOLES OF BEAM FITTING PER 51-00-16, NO DEFECTS NOTED.OK TO CONTINUE. INSTALLED NEW RT HAND INBOARD FLAP INBOARD TRACK FWD SUPPORT FITTING IAW ECRA 5740-02900. MACHINIST LOCATED NEW HOLES IN FITTING. CYCLED FLAPS NO DEFECTS NOTED AT THIS TIME