What was found
FUSELAGE EXTERNAL SURFACE FR-23 STRG 23 DENT REQS FURTHER EVAL L OG #3534741 AT HAECO LCQ PER REF NO.9297300 BY MECH N078570 REMOVED DAMAGE & REPAIRED EXTERNAL SURFACE FR23 STRG23 PER SRM 5 3-00-11-300-029. NOMINAL SKIN THICKNESS 0.047". DOUBLER THICKNE SS 0.050". SRI 53-00-11-205-017 REQUIRES INSP THRESHOLD FROM TIM AIR OF 60,000 FC & 120,000 FH, SUBSEQUENT INSPS & INSP METHODS T BD. HAECO NR 23300. OKAY TO DIP INSPECTION THRESHOLD FROM TIME OF REPAIR EMBODIMENT FOR 60,000FC/120,000 FH SUBSEQUENT INSPECTIONS TBD REF SRI 53-00 -11-205-017. TOMC-APPROVAL FROM SC1ELBYC COMMENT TOMC APPROVED: QC REVIEWED TOMC APPROVED: QC REVIEWED INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE.