What was found
REF LP 9609737 DENT AT STR 24R BETWEEN STA 500D AND 500E FOUND OUT OF LIMITS DUW TO PROXIMITY TO LAP SEAM AREA REF AAR N/R 9879010 ACCOMPLISHED INTERIM REPAIR AT FUSLAGE SKIN BETWEEN STA 500D AND 500E AND BETWEEN STR 22R AND STR 25R PER UNITED ECRA 5331-02292 ACCOMPLISHED INSPECTION REQUIRMENTS ON OR BEFORE A/C REACHES 50,000 TFC PLANNING TO CONTACT ENGINERING AFTER 47,000 CYC BUT BEFORE 48,000 CYC REF ELBLP 8238147 FOR DIP ADD EMP:V900455