What was found
LEADING EDGE FLAPS TRANSIT LIGHT STAYS ON 2 PLACED #2 SLAT INDICATION ON MEL 2704E. REMOVED BULBS FROM AMBER INTRANSIT LIGHT ON FWD PANEL. C\W MEL MX PROCEEDURES. FOUND MSG # 27-81202 ON FSEU AND PULLED AND COLLORED C.B. FOR ADD FAULT: 27-81202 INDICATIONS. FLAPS AND SLATS OPS NORMALLY EXCEPT #2 SLAT IN TRANSIT STALL WARNING ASYMMETRY MODE CIRCUIT BREAKER ON P18-2 PER MEL. DISPATCH DESK: 07 NAME: MIKE DATE: 11-NOV-18- NOC DESK: 07 NAME: MIKE DATE: 11-NOV-18- TOMC APPROVED PLACED #2 SLAT INDICATION ON MEL 2704E. REMOVED BULBS FROM AMBER INTRANSIT LIGHT ON FWD PANEL. C\W MEL MX PROCEEDURES. FOUND MSG # 27-81202 (SL2 PROX OUTBD) ON FSEU AND PULLED AND ADD FAULT: 27-81202 TRANSIT INDICATIONS. ON P18-2 PER MEL. FLAPS AND SLATS OPS NORMALLY EXCEPT #2 SLAT IN COLLORED C.B. FOR STALL WARNING ASYMMETRY MODE CIRCUIT BREAKER AHM UPDATE: AFTER VIEWING SCEPTRE DFD REPORT, LOOKS LIKE ITS POSSIBLE ONE OF THE #2 L/E SLAT SENSORS MIGHT BE AT FAULT, PLEASE RUN AMM TASK 27-88-11-700-801, SENSOR LISTED IF NEEDED. INTERAGATED FSEU AND FOUND SL2 O/B PROXIMITY SENSOR FAULTED SHOW ING A NEAR CONDITION. R&R LEADING SLAT PROXIMITY SENSOR ON #2 SLAT, (OUTBOARD) PER AMM 27-88-11. PERFORMED ADJUSTMENT TEST PER AMM 27-88-11-700-801. OP CKS GOOD. ADD EMP:352797