What was found
GEN 1 FAULT REF TSM TASK 24-20-00-810-803-A, STEP 4 A . INSPECTED POWER FEEDER CONNECTOR AT FIREWALL. NO BURNING/ARCING DAMAGE OR CORROSION. RECONNECTED POWER FEEDER CONNECTOR. VERIFIED NO BURNING/ARCING OR SIGNS OF CORROSION ON POWER FEEDER CONNECTOR AT PYLON PER TSM 24-20-00-810-803-A. VERIFIED INSTALLATION OF PER FEEDER CONNECTOR TO PYLON. REMOVED AND REPLACED #1 IDG UP TO AND INCLUDING STEPS 4. F. (16) PER AMM 24-21-51 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1163111 SN OFF 0232 GENERATOR, INTE OFF 31-2411-9-0001 0232 ON 31-2411-9-0001 1041 FINISHED INSTALLATION OF #1 ENGINE IDG REF MM 24-21-51. OPS AND LEAK CHECKED GOOD. COMPLIED WITH INSPECTION PORTION OF NUMBER ONE ENGINE IDG ENGINE INSTALLATION REF 24-21-51 AND GMM 09-10-05