What was found
(B757-533-003) AFTER REMOVAL FOUND APU AIR INLET DOOR HOUSING CU T OUT LOWER FUSELAGE ANGLE FROM STA 1790 TO 1822 CORRODED. REF STSAA N/R 0032462 APU INLET DOOR CUT OUT LWR ANGLE AT STA 1790-1822 S-6R FOUND OUT OF LIMITS IAW B757-200 SRM 53-80-15-A1-F101 L=1.5, W=2.0, D=.023 . REMOVED AND INSTALLED NEW LWR ANGLE P/N 148N3152-1 IAW B757-2 00 SRM 51-40-02 PG 1-10 AND DWG148N3105. THIS IS TRANSCRIBED IN FORMATION ACCOMPLISHED AND RECORDED ON STSAA PAPER N/R 0032462 SEE ABOVE. WORK WAS ACCOMPLISHED BY MECH V919728 AND INSPECTED B Y V919676.