What was found
LH UPPER SURFACE, FOUND FLUID ENTRAPMENT AT 18.5 INCHES FROM I/B EDGE AND 6.25 INCHES FROM TRAILING EDGE. DEFECT IS 4.75"X4" IN SIZE AD RELATED TASK 2017-22-03 PER HAECO LCQ NR 9292259 GENERAT ED BY V916887 A3NB-55-4-6016 UPON EVALUATION OF LEFT ELEVATOR UPPER SKIN 18.5 IN FROM I/B 6.25 IN FROM T/E ZONE 3 DUE TO CLOSE DISTANCE JOINED 3 EA REPAIRS INTO 1 STRUCTURAL REPAIR NR 22258/9292258 & 22260/ 9292260 TOTAL SIZEE 28.5 IN. APPLIED STRUCTURAL REPAIR IAW A320 SRM 55-21-11-300-010 CATEGORY A REPAIR AT HAECO LCQ ON HANGAR NR V061744 9292259 BY MECH V080675 SUPERVISOR V061767 RII INSP C/W BY LC-23