What was found
LH UPPER SURFACE, FOUND FLUID ENTRAPMENT AT 19.75 INCHES FROM I/ B EDGE AND 3.5 INCHES FROM TRAILING EDGE. DEFECT IS 2"X1.5" IN S IZE AD RELATED TASK 2017-22-03 PER HAECO LCQ NR 9292258 GENERATE D BY V916887 UPON EVAL OF LEFT ELEVATOR UPPER SURFACE 19.75 IN FROM I/B 3.5 I N FROM T/E ZONE 3 DUE TO CLOSE DISTANCE JOINED 3 EA REPAIRS INTO 1. NR 22260/9292260 & 22259/9292259 TOTAL SIZE 28.5 IN. APPLIED STRUCTURAL REPAIR IAW A320 SRM 55-21-11-300-010 CATEGORY A REPA IR AT HAECO LCQ ON HANGAR NR 9292258 SUPERVISOR V061767 RII INSP C/W BY LC-32 V077953