What was found
LH UPPER SURFACE, FOUND FLUID ENTRAPMENT AT 22 INCHES FROM I/B E DGE AND 5.5 INCHES FROM TRAILING EDGE. DEFECT IS 5"X3.5" IN SIZE PER HAECO LCQ NR 9292260 GENERATED BY V916887 A3NB-55-4-6016 UPON EVAL OF LH ELEVATOR UPPER SURFACE 22 IN FROM I/B 5.5 IN FROM T/E DUE TO CLOSE DISTANCE JOINED 3 EA REPAIRS I NTO 1. NR 22259/9292259 & 22258/9292258 TOTAL SIZE 28..5 IN. ZON E 3 APPLIED STRUCTURAL REPAIR IAW A320 SRM 55-21-11-300-010 CATE GORY A REPAIR AT HAECO LCQ ON HANGAR NR 9292260 SUPERVISOR V061767 RII INSP C/W BY LC-32 V077953