What was found
AFT WET AREA BETWEEN STA 986.5 TO STA 1000 10 INCH RIGHT FROM BL 0 INTERCOSTAL CRACKED. (REF NR 9882236) REMOVED DAMAGED INTERCOSTAL FROM AFT WET AREA BETWEEN STA 986.5 ERFORMED ON AFFECTED AREA AS PER SRM 51-10-02, NO CRACKS NOTED O NLY DEEP SCRATCH. ORIGINAL THICKNESS .075" LOSS .013" REMAINS .0 62" OUT OF LIMITS PER SRM 53-70-51. FABRICATED NEW INTERCOSTAL TO STA 1006, 10" RIGHT FROM BL0 AS PER SRM 51-40-02. BLEND OUT P 1. INSTALLED NEW PART PER SRM 51-40-02. SECTION PER DRAWING 147A5702. TREATED AND PRIMED PER SRM 51-20-0