What was found
B757-06-3-0230 2EA DENTS ON AFT CARGO LT FRAME UPPER FLANGE AT S TA 1520 BETWEEN STR 25L-26L. RG21. REF N/R 0040325. -26L FOUND OUT OF LIMITS IAW SRM 53-00-07-A1 L= 1.0, W= .5, D= .032. CUT OUT DAMAGES AND ACCOMPLISHED PERMANENT REPAIR IAW SRM 53-00-07-R5 WITH REPEAT INSPECTION ZONE 1 AT 50 ,000 F/C AND INTERVAL 12,000 F/C PER TABLE 2 FIG 201 PG 211. CUR AFT CARGO FRAME UPPER FLANGE DENT AT STA 1520 BETWEEN 5-25L TO 5 RENT F/C 20648 SEE CONT FORM: 850771. REPAIRED PER SRM 53-00-07 REPAIR 5 REQUIRES REINSPECT PER CAT B TABLE II ZONE 1 M 50000 AIRFRAME FLIGHT CYCLES RII INSPECTION C/W BY ONSITE INSP. TOMC APPROVES PERMANENT REPAIR OF AFT CARGO FRAME UPPER FLANGE DENT AT STA 1520 BETWEEN 5-25L TO 5-26L PER SRM 53-00-07 REPAIR 5 WITH THE FOLLOWING INSPECTION REQUIREMENTS REF TABLE II.