What was found
NEED TO COMPLY WITH AMM 29-00-00-280-006-A01 CHECK OF Y HYD SYS AFTER PUMP FAILURE OR OPERATION IN A POSSIBLE CAVITATION COND. FOUND PARKING BRAKE VALVE LEAKING REPLACED PER AMM 32-45-14-400 REPLACED NR 2 ENG DRIVEN PUMP DUE TO CAVITATION PER AMM 29-13-51-4 00 REPLACED YELLOW LOW PRESSURE FILTER PER AMM 29+-13-44-400 REP LACED YELLOW HP FILTER PER AMM 29-13-45-610-001-A PERFORMED ENG RUN NR 2 LEAK CKS NONE FOUND ROTABLE PARTS CHANGE WAS INDICATED - TT # 1452258 SN OFF 0494 TT # 1259843 SN OFF 1466 IPC REFERENCE # 29-13-51-01B VALVE, PARKING OFF 31-3245-9-9003 0494 ON 31-3245-9-9003 7400.