What was found
RH HORIZONTAL STABILIZER SKIN AT STAB STATION 140, 24" AFT OF FRONT STAB I/B FASTENER ROW OPPOSITE OF DRAIN HOLE 1" CRACK BETW EEN FASTNERS(MARKED). FOUND ON SMB C-CHECK WRITE UP 9646070. REP AIR PER SRM 55-10-01 REPAIR 11. RH LOWER HORZ. STAB CRACK REPAIRED PER SRM 55-10-01 REPAIR 11. O N SMB DOCK WRITE UP 9646070. REQUIRES REINSPECTION PER SRM 55-10 -01 REPAIR 11 TABLE 204 PAGE 223. 56,000 TOTAL FLIGHT CYCLES. ADD EMP:U250639 INTERVAL 9000 FLIGHT CYCLES. PER SRM 55-10-01 REPAIR 11. O SMB DOCK WRITE UP 9646070. REQUIRES REINSPECTION PER SRM 55-10 -01 REPAIR 11 TABLE 204 PAGE 223. 56,000 TOTAL FLIGHT CYCLES. THEN EVERY 9000 CYCLES THERE AFTER TOMC APPROVED, PLACED ON DIPRH LOWER HORZ. STAB CRACK