What was found
L/H FR 16 DOOR STOP FITTING #1 BOTTOM FITTING, I/B LOWER FASTENE R HOLE HAS CRACK INDICATION REPAIRED I/B LOWER FASTENER HOLE OF DOOR STOP #1 ON FR 16 L/H IA W ECRA 5311-02077 . ACCOMPLISH THE INITIAL INSPECTION REQUIREMEN TS AT THE LH FR16 DOOR STOP #1 HOLE #3 AS PER PART 2 OF ECRA 531 ADD EMP:U354480 1-02077 ON OR BEFORE THE AC REACHES 37,382 TOTAL FLIGHT CYCLES. ACCOMPLISH REPEAT I NSPECTION AT INTERVALS NOT TO EXCEED 12,000 AC FLIGHT CYCLES THEREAFTER OK TO DIP PER ECRA. ACP INITIAL INSP REQ AT THE LH FR16 DR STOP FITTING #1 HOLE #3 AS PER PART 2 OF ECRA 5311-02077 ON OR BEFORE THE ACFT REACHES 37,382 TOTAL ACFT FLT CYC. ACP THE REPEAT INSP AT INTERVALS NOT TO EXCEED 12000 ACFT FLT CYC THEREAFTER. TOMC-APPROVAL FROM SC1ELBYC COMMENT QC RECORDS UPDATE QC REVIEW INIT:37382TAFC INIT WILL ITO TO RIR RIR:12000FC THEREAFTER...ML/U359635