What was found
AFT PIT STR 42L BETWEEN FR58 AND FR59 HAS CORROSION, SUPPORT TAS K, PER LCQ NR 9293228. REPLACED STRINGER SECTION 42L FROM FR57 TO FR60 IAW SRM 53-00-13 -300-001. SUPPLEMENTAL INSPECTIONS REQUIRED IAW SRI 53-00-13-205 -001 TABLE 05 BEGINNING AT 60,000 FC / 120,000 FH FROM REPAIR EMBODIMENT WITH SUBSEQUENT INSPECTION INTERVALS TBD. INSPECTION METHOD TBD. APPROVED CARRY FOR 60,000 CYCLES OR 120,000 HOURS AFTER SUBSEQUENT REPAIR. TOMC-APPROVAL FROM SC1ELBYC COMMENT QC REVIEWED QC REVIEWED RECORDS UPDATE .JF RECORDS UPDATE ..JF T/A: 60,000 FC OR 120,000 FH ...JF