What was found
DATA TRANSFER DURING SETUP FOR RT OVER WING EMER EXIT OPS CHK, FOUND NIPPLE ON CABLE CONNECTOR FROM INFLATION RESERVOIR SHEARED OFF AND NOT CO NNECTED, A3NB-52-3-6028, PER NR 9292025. RMVD & RPLCD RT OVER WING SLIDE INFLATION RESERVOIR IAW AMM 25-62-46-000-001-A & 25-62-46-400-001-A. S/N: A-1684, DUE 21 AUG 19, INSP PERFORMED, N078625 ROTABLE PARTS CHANGE WAS INDICATED - TT # 1324189 SN OFF 5889 IPC REFERENCE # 2560-02442 BOTTLE, AY-OFFW OFF 31-2560-9-9001 5889 ON 31-2560-9-9001 8231.