What was found
ROTO PROBE INSPECTION OF DOUBLE JOGGLE SHOW S CRACK INDICATION AT DOOR STOP #7 LOCATION (UPPER LOCATIONS) RH SIDE, 3RD FASTENER OF AFT COLUMN INTERIM REPAIR PERFORMED PER PART 1 OF ECRA 5311-02125.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ROTO PROBE INSPECTION OF DOUBLE JOGGLE SHOW S CRACK INDICATION AT DOOR STOP #7 LOCATION (UPPER LOCATIONS) RH SIDE, 3RD FASTENER OF AFT COLUMN INTERIM REPAIR PERFORMED PER PART 1 OF ECRA 5311-02125.