What was found
LT HORIZONTAL STAB HAS 1 SKIN CRACK AT APPROX., STAB STA. 120.30 10 1/2 " FWD OF THE AFT SPAR, APPROX 1/4" LONG. REF. FLEET CYCLE LOG PAGE 9666039 FOR REPAIR CORRECTIVE ACTION. DIP REQUIRED PER SRM 55-10-01 REPAIR 11. DEFECT WAS REPAIRED PER REPAIR 11 OF SRM 55-10-01 REPAIR 11 PG 206. THIS IS A CATEGORY B REPAIR WITH SUPPLEMENTAL INSPECTIONS GIVEN IN PARA 5. / REPAIR 11. TABLE 204 PG 223. CATEGORY B INSPECTION REQUIREMENTS INSPECTION THRESHOLD OF 56,000 TOTAL FLT CYCLES WITH REPEAT INSPECTIONS AT 9,000 FLT CYCLES DV AND LFEC METHOD.