What was found
BULK CARGO STA 1540 STR 37L AREA INTERIOR SKIN FOUND CORROSION. REPAIRED IAW ECRA 5331-02373PART 1 ITERIM REPAIR AT NRC TJE518820 INSP 156019. REPAIR IS CONSIDERED PERMANENT AS LONG AS REINSPECTION REQUIREMENTS OF PART 2 ARE COMPLIED WITH. ACCOMPLISH THE INSPECTION PER ECRA 5331-02373 PART 2 ON OR BEFORE THE AIRCRAFT REACHES 37500FC. REPEAT INSPECTIONS AT INTERVALS NOT TO EXCEED 9000FC THEREAFTER. DURING 8C FOUND INTERIOR SKIN CORROSION AT STATION 1540 AT STRINGER 37L. PER ECRA 5331-02373 COMPLY WITH REPAIR PART 1. INITIATE DIP TO ACCOMPLISH INSPECTION PER PART 2 ON OR BEFORE AIRCRAFT REACHES 37500 FLT CYCLES AND REPEAT INSPECTIONS AT 9000 FLIGHT CYCLES THEREAFTER. TOMC-APPROVAL FROM SC1ELBYC COMMENT QC REVIEWED RECORDS.