What was found
RT HOR. STAB. STA 92.70 SKIN CUT OUT FOR RIB REPAIR REF F/C N/R 9669328 SKIN HAS BEEN REPAIRED IAW SRM 55-10-01 REP 11 AT STA 92.70 INSP THRESHOLD AT 56000 TOT FLT CYCS FOLLOWED BY REPEAT INSP AT EACH SUBSEQUENT 9000 FLT CYCS REF STEP 5 TABLE 204 TOMC APPROVED, PLACED ON DIP TOMC-APPROVAL FROM SC1ELBYC COMMENT VERIFIED DIP APPROVAL. QC REVIEW QC REVIEW RECORDS UPDATE INIT: 56,000 TAFC RIR: 9000 FC THEREAFTER...SN.