What was found
LT HORIZONTAL STAB CRACKED AT STA 193.9. REPAIRED LH HORIZONTAL LOWER INSPAR SKIN AT STA. 193.9 REF 737 SRM 55-10-01 REPAIR 11. DIP REQUIRED-INSPECTION THRESHOLD OF 56000 TOTAL FLT CYCLES AND 9000 FLT CYCLES INTRVLS THERAFTER. ADD EMP:U105472 TOMC APPROVES DIP, INSPECTION THRESHOLD OF 56000 FLT CYCLES AND A REPETITIVE DVI AND LFEC AT 9000 FLT CYCLES PER SRM 55-10-01 REPAIR 11, TABLE 204 TOMC-APPROVAL FROM SC1ELBYC COMMENT VERIFIED REPAIR INSTALLATION AND DIP INITIATION. REF SRM 55-10-0 1 REPAIR 11. SEE FLEETCYCLE L/P# 9671099 FOR ALL WORK ACCOMPLISH ED. INSPECTIONS CREATED BY AUTODIP PENDING AIRCRAFT RECORDS AUDIT & UPDATE. QC QC