What was found
LT. HORIZONTAL STAB. CRACKED AT STA 147.9. REPAIRED LH HORIZONTAL LOWER INSPAR SKIN AT STA. 147.9 REF 737 SRM 55-10-01 REPAIR 11. DIP REQUIRED-INSPECTION THRESHOLD OF 56000 TOTAL FLT CYCLES AND 9000 FLT CYCLES THERAFTER. ADD EMP:U105472 TOMC APPROVES DIP, INSPECTION THRESHOLD OF 56000 FLT CYCLES AND A REPETITIVE DVI AND LFEC AT 9000 FLT CYCLES PER SRM 55-10-01 REPAIR 11, TABLE 204 TOMC-APPROVAL FROM SC1ELBYC COMMENT VERIFIED INSTALLATION OF REPAIR AND DIP INITIATION.REF SRM 55-10 -01, REPAIR 11.