What was found
ON REMOVAL OF SUPPORT FRAME, FOUND STRINGER SECTION CORRODED AT STR 24 FR 70R. A CORROSION RESULTED IN 100% MATERIAL LOSS OF STRINGER SECTION @ S TR 24 FR70R. REMOVED PART AND MATCHDRILLED, DEBURRED, AND INSTAL LED NEW STRINGER SECTION @ STR 24 FR70R. APPLIED TOP COATING TO FASTENERS IAW SRM 51-72-11-911-001.