What was found
AFT CABIN FLOORBEAM AT BS 985.5 LBL 44 HAS CORROSION AROUND A FASTENER HOLE AS MARKED. REMOVED FLOORBEAM AND RECEIVED,DRILLED AND DEBURED NEW INTERCOSTALLOCATED,DRILLED AND DEBURED NEW EXTRUSION,ALODINE SRM 51-40-02,SRM 51-40-05, SRM 53-70-51,REPAIR ALTERNATIVE AND PRIMED, INSTALLED NEW INTERCOSTAL AND NEW EXTRUSION.